OPRA Pharmacokinetics and Pharmacodynamics QUESTION #3850
Question 1
What is the most reliable pharmacokinetic measurement to demonstrate bioequivalence between two tablet formulations containing the same drug dose?
  • Disintegration time
  • Dissolution time
  • Serum concentration✔️
  • Rate of excretion
Correct Answer Explanation
Bioequivalence is established by comparing pharmacokinetic parameters ($\text{AUC}$, $C_{\max}$, and $T_{\max}$) derived from serum concentration–time profiles after administration of both formulations.