According to ACI 318-95 load combination recommendations, the load factor applied to wind load \(W\) is:
Correct Answer Explanation
Per ACI 318-95, the load combination including wind is \(U = 0.75(1.4D + 1.7L + 1.7W)\), giving an effective wind load factor of \(0.75 \times 1.7 = 1.275 \approx 1.3\). Also used as \(1.3W\) directly in some combinations.