Back to Questions
Civil Engineering
QUESTION #6620
Question 1
For a 'Built-up' steel member, the individual components must be connected at intervals such that the slenderness ratio of any individual component does not exceed the:
Correct Answer Explanation
To ensure the built-up member acts as a single unit, the slenderness of individual components between connectors ($l/r_i$) must be less than or equal to the overall slenderness ($KL/r$) of the member.
Sign in to join the conversation and share your thoughts.