Back to Questions
MBBS
QUESTION #10282
Question 1
On tuning fork testing, a patient's Rinne test shows bone conduction perceived louder/longer than air conduction (a 'negative' Rinne) in the affected ear, and the Weber test lateralizes to that same affected ear. This pattern indicates:
Correct Answer Explanation
Normally air conduction exceeds bone conduction (positive Rinne). A negative Rinne (bone > air) indicates impaired sound transmission through the external/middle ear — conductive hearing loss — and in conductive loss the Weber test lateralizes toward (is heard louder in) the affected ear, since ambient masking noise is reduced there.